Roof exhaust fans for commercial kitchen exhaust, grease and smoke removal, warehouse ventilation, factory roof exhaust, mechanical rooms, and MEP projects across Saudi Arabia.

KSA project supply
Technical selection
Approval documents
Roof exhaust fans installed on an industrial facility in Saudi Arabia
Quick Selection Answer

Match the roof fan to the exhaust duty

Upblast roof fans are generally used for kitchen grease exhaust, downblast fans for weather-protected general exhaust, centrifugal fans for higher system resistance, and axial roof fans for high airflow at lower pressure. Final selection should confirm CFM, static pressure, roof opening, voltage, and duty.

Roof Exhaust Ventilation

Roof mounted exhaust fan supply for Saudi Arabia projects

A roof exhaust fan removes contaminated, warm, stale, or grease-laden air through a roof opening, curb, or duct system. Contractors, MEP engineers, restaurants, factories, warehouses, and procurement teams can compare the main options here before requesting a Saudi Arabia project quotation.

What is a roof exhaust fan?
A roof exhaust fan is a roof-mounted ventilation fan that removes air from a building through ductwork, roof openings, or roof curbs. It is commonly used where exhaust air should leave the building from the rooftop instead of a wall opening.
Where is it used?
Common Saudi Arabia applications include commercial kitchens, restaurants, factories, warehouses, workshops, mechanical rooms, toilets, stores, and commercial buildings that need reliable roof ventilation.
How is it selected?
Selection depends on airflow, static pressure, roof curb or opening size, voltage, phase, discharge direction, air temperature, grease content, accessories, quantity, and project city.
Product Range

Roof fan products for KSA projects

Choose the nearest roof fan type, then send CFM or m3/h, static pressure, roof opening, voltage, quantity, and project city for selection support.

Brand names and trademarks belong to their respective owners. Product availability, model data, warranty, and supply-channel status are confirmed during quotation.

Selection Logic

Which roof exhaust fan should you choose?

Compare the main roof fan types before sending an inquiry. This helps contractors, MEP engineers, and procurement teams match the fan type with the actual exhaust duty.

Upblast Roof Fan
Compare
Commercial kitchen exhaust, restaurant hood exhaust, and grease exhaust
RemovesGrease, smoke, heat, and odorSelectionVertical discharge with roof curb and grease drain or cup options
View Upblast Roof Fan
Downblast Roof Fan
Compare
General building exhaust, toilets, stores, and mechanical rooms
RemovesStale air, odor, and warm airSelectionWeather-protected downward discharge for non-grease exhaust
View Downblast Roof Fan
Centrifugal Roof Fan
Compare
Commercial and industrial exhaust with higher resistance
RemovesHeat, fumes, process air, and general exhaustSelectionUseful when ductwork or system resistance is higher than free discharge
View Centrifugal Roof Fan
Axial Roof Fan
Compare
High-airflow, lower-pressure roof ventilation
RemovesWarm air, warehouse air, and general exhaustSelectionUseful for factories, warehouses, and large ventilation openings
View Axial Roof Fan
RMD Direct Drive Roof Fan
Compare
Compact roof or wall exhaust points
RemovesStale air, heat, and light fumesSelectionDirect-drive selection for smaller to medium roof exhaust duties
View RMD Direct Drive Roof Fan
Commercial Kitchen Exhaust

Roof fan for kitchen grease, smoke, heat, and odor removal

Commercial kitchens need a roof exhaust fan that can move grease-laden air, smoke, heat, and odor from the hood through the duct system to a safe roof discharge point. Upblast roof fans are commonly selected when vertical discharge and grease exhaust handling are required.

For restaurants and central kitchens, the quotation should not be based on fan size alone. The hood airflow, duct routing, static pressure, roof curb size, discharge direction, grease drain requirement, voltage, and approval documents should be reviewed before selection.

Grease exhaust
Smoke removal
Heat extraction
Odor control
Roof fan for kitchen exhaust
For restaurants, central kitchens, cloud kitchens, hotels, and food production areas that need roof discharge for grease, smoke, heat, and odor removal.
Roof exhaust fan for warehouses
For stale air removal, heat relief, and ventilation support in storage, logistics, and industrial buildings.
Factory roof exhaust ventilation
For production areas, workshops, process rooms, and facilities that need roof-mounted extraction for warm air or fumes.
Commercial building roof fans
For toilets, service rooms, basements, equipment rooms, and general building exhaust systems.
Before Quotation

What to send for correct roof fan selection

Correct selection helps avoid weak airflow, wrong motor voltage, noise issues, and quotation delays. Share these details before model selection so the fan can be matched to the site condition.

01

Application

Kitchen exhaust, warehouse exhaust, factory ventilation, toilet exhaust, or mechanical room.

02

Airflow and pressure

Send required CFM or m3/h and static pressure. Duct length, bends, filters, and louvers affect selection.

03

Roof opening

Send the roof opening, curb size, or available slab opening before quotation.

04

Electrical supply

Confirm 220V or 380V, single or three phase, and the required 60 Hz supply.

05

Accessories

Confirm roof curb, backdraft damper, bird screen, controller, weather hood, or grease cup.

06

Project and approvals

Send quantity, Saudi project city, drawings, and the datasheet or approval documents required.

Buying Process

How roof fan quotation support works

Roof exhaust fan inquiries often come from drawings, BOQs, site photos, or urgent replacement requirements. A simple step-by-step process keeps the buying path clear for contractors and procurement teams.

01

Share requirement
Send application, airflow, roof opening, voltage, phase, quantity, and project city.

02

Review fan type
We check whether an upblast, downblast, centrifugal, axial, or another roof fan type is suitable.

03

Prepare quote
The quotation can include fan details, motor information, accessories, delivery notes, and available documents.

04

Support approval
Available datasheets, catalog references, and company documents can support procurement or consultant review.
Saudi Arabia Supply

Roof exhaust fan supplier for KSA cities

We support roof fan inquiries for contractors, restaurants, factories, warehouses, facility teams, procurement departments, and MEP engineers across Saudi Arabia.

Voltage review

220V / 380V, phase, and 60 Hz requirement

Site review

Roof opening, curb size, and duct connection

Documents

Datasheets, catalogs, submittals, and company files

Quotation

Product, accessories, quantity, and city details

Common service cities
Saudi Arabia roof fan inquiries and project supply support.
Riyadh
Jeddah
Dammam
Khobar
Makkah
Madinah
Jubail
Yanbu
Qassim
Taif
Tabuk
Abha
Installation Photos

Roof exhaust fan installation photos

Representative roof fan installations and arrangements. Project-specific models, curbs, and accessories are confirmed during quotation.

Upblast roof exhaust fan installed on a roof curb
Upblast roof fan on a roof curb
Roof top centrifugal exhaust fan installed on a building roof
Roof-top centrifugal fan installation
Upblast roof exhaust fan unit
Upblast roof exhaust fan unit
Downblast roof exhaust fan unit
Downblast roof exhaust fan unit
Centrifugal roof exhaust fan unit
Centrifugal roof exhaust fan unit
Upblast roof fan with grease drain accessories
Upblast fan with grease accessories
Procurement Support

Documents and accessories available on request

For procurement and consultant approval, we can help prepare fan details, accessory requirements, catalog files, technical submittals, and company documents before quotation.

Roof curb
Backdraft damper
Bird screen
Speed controller
Grease cup
Weather hood
Datasheet
Product size, airflow, motor, voltage, and accessory details.
Technical Submittal
For contractor, consultant, and procurement approval workflow.
Performance Reference
Model schedule, airflow range, pressure reference, and curve files where available.
Company Documents
Applicable CR, VAT, certificate, catalog, and quotation files can be shared on request.
Selection References

Standards and references behind our roof fan selection

Roof fan selection for Saudi Arabia projects is reviewed against recognized ventilation, fire-safety, and fan-testing references, so contractors, MEP engineers, and consultants receive technical justification instead of a fan size guess.

ASHRAE Standard 62.1

Ventilation for acceptable indoor air quality. Referenced when reviewing exhaust airflow and makeup air quantities for commercial buildings.

NFPA 96

Ventilation control and fire protection of commercial cooking operations, including hood exhaust, grease ducts, and roof discharge practice.

AMCA / ISO 5801 Test References

International fan performance testing references used when reviewing airflow and static pressure curves for roof fan models.

Saudi Building Code (SBC)

Mechanical and ventilation provisions applied by consultants and authorities on building projects across Saudi Arabia.

SASO / Saber Conformity

Electrical products supplied into Saudi Arabia are expected to follow applicable SASO requirements and Saber platform conformity at import.

Manufacturer Catalogs & Submittals

Selection is backed by brand datasheets, performance curves, dimension drawings, and technical submittals prepared for consultant review.

These references support technical discussion during selection. Final compliance must be verified against project specifications, consultant requirements, and the authority having jurisdiction.

Roof Fan FAQ

Answers for Saudi Arabia roof fan buyers

Quick answers for roof fan selection, price factors, roof vs wall mounting, maintenance, Saudi city supply, and approval documents.

For kitchen exhaust, an upblast roof fan is usually the first option because it discharges vertically and is better suited for grease, smoke, heat, and odor removal from hood exhaust systems. Final selection depends on CFM, static pressure, roof curb size, voltage, and local project requirements.

Saudi Arabia Quotation Support

Request roof exhaust fan quotation

Send your application, airflow, static pressure, roof opening or curb size, voltage, quantity, and project city. The technical sales team can guide the nearest roof fan type before quotation.