Industrial Axial Fans in Saudi Arabia
In summer, a warehouse can get hotter inside than the street outside. The heat makes your team tired and slow, and the old wall fan does not help much. It is fair to want a place where your staff can work without feeling sick from the heat. An industrial axial fan pulls the hot air out and brings fresh air in, so the heat does not build up under the roof.
We supply single phase and three phase models, including the popular 630 mm size, for wall or duct mounting. Explosion proof versions are also available for fuel, paint and chemical areas. Send us your building size or a photo of your old fan's nameplate on WhatsApp. How big is the space you need to ventilate?

- 20+ years in Saudi Arabia
- 2 years warranty
- 1000+ Satisfied Clients
- Fast Delivery Across KSA
What Is an Axial Fan?
An axial unit has blades like a propeller that push air straight through, in the same line as the motor shaft. It moves a lot of air with little power, but it does not build much pressure. That makes it the right choice for walls, short ducts and open halls. When the air has to travel through a long duct, filters or a hood, a centrifugal blower does the job better.Centrifugal blowers
Axial units are used widely across the Kingdom. Invest Saudi put local demand for industrial fan blades at USD 92 million in 2018, driven largely by axial units used for cooling and exhaust. You will find them in warehouses, factories, workshops, car parks, farms and cold stores.

Propeller, Tube Axial or Vane Axial?
The ASHRAE Handbook sorts these fans into three types. The difference is how much pressure each one can build, and that decides where it fits. Choose the simplest type that can handle the resistance in your system.
| Type | How it is built | Pressure | Where it fits |
|---|---|---|---|
| Propeller | Blades in a flat plate or ring | Low, close to free air | Through a wall with no duct, fresh air intake |
| Tube axial | Blades inside a short tube with a small gap at the tips | Medium | Short ducts, spot cooling, portable fans |
| Vane axial | A tube axial model with guide vanes behind the blades | Higher, with better efficiency and less noise | Longer ducts, tunnels, car parks |
Our Axial Fan Range
We bring in axial units from factories in China, the UAE, the United States and other countries, so we can match most sizes and duties. Each one is chosen for 60 Hz Saudi power, at 220 V single phase or 380 V three phase. They come for wall or plate mounting and for duct or cased mounting.
630 mm and Other External Rotor Fans
The 630 mm external rotor fan is a size buyers in the Kingdom ask for often, used for cooling, condensers and general exhaust. The motor sits inside the hub of the blades, which keeps the unit short and easy to fit in a ring or a box. We have it in single phase for sites without three phase power. Tell us if you need it to suck air out or blow air in, because the two are different versions.
| 630 mm model | Supply | Speed | Power | Airflow | Noise |
|---|---|---|---|---|---|
| YWF4E630 | 220 V single phase | 1,360 rpm | 750 W | 11,600 m³/h free air, 11,258 m³/h at 20 Pa | 75 dB |
| YWF4D630 | 380 V three phase | 1,390 rpm | 1,450 W | 15,249 m³/h at 20 Pa | 79 dB |
These are typical factory figures for this size, and the exact numbers vary a little between factories. Send us your duty and we will share the curve for the model we supply. That way you know the performance before you order.
The model code tells you most of what you need. Here is how to read a code such as YWF4E630S. Codes vary a little between factories, but most follow this pattern.
| Part of the code | What it means |
|---|---|
| YWF | External rotor axial type |
| 4 | 4 pole motor |
| E | Single phase, with a capacitor |
| D | Three phase |
| 630 | Blade diameter in mm |
| S or B | Suction (pulls air) or blowing (pushes air) |
Explosion Proof Axial Fans
Fuel stations, paint booths, battery rooms, chemical stores and gas plants can have flammable vapour in the air. A normal motor can spark and set it off. These models use sealed motors and spark resistant parts made for these zones. Ask for the ATEX or IECEx certificate that matches the hazardous zone on your drawings, and we will select the model to suit.
Wall, Roof and Duct Models on Other Pages
Some axial ranges have their own pages. Square steel and shutter fans for walls are on our wall fan page, and the axial roof fans are on our roof fan page. Belt drive models for round ducts sit on our inline fan page, and drum fans are on our portable fan page.Wall mounted fansRoof fansInline fansPortable fans
IP44 or IP55?
The IP rating shows how well a motor keeps out dust and water. Our range includes both IP44 and IP55 motors. The first number is for solids, and the second is for water.
| Rating | Dust | Water | Good for |
|---|---|---|---|
| IP44 | Keeps out objects larger than 1 mm | Splashing water | Clean, dry rooms and plant rooms |
| IP55 | Dust protected | Low pressure water jets | Dusty warehouses, outside walls, areas that are washed down |
In most Saudi warehouses and workshops, fine dust gets everywhere, so IP55 is the safer choice. On outside walls and roofs, IP55 also copes better with blowing sand and washing. IP44 is fine for clean, dry rooms where cost matters more.
Built for Saudi Heat and Power
Saudi power runs at 60 Hz, with 220 V single phase in most shops and small units, and 380 V three phase in factories. Single phase fans are easy to connect and suit small workshops and farms. Three phase fans run smoother and are the norm for larger sizes. Under SASO 2893/2018, general purpose three phase motors must meet the IE3 efficiency class, so ask for it on the nameplate of larger fans.
Heat is the other test. Summer air in the Kingdom can pass 50 °C, and a motor rated for 40 °C at full load needs a higher rating to run in that heat. Ask for a motor rated for your real ambient temperature, with class F insulation. A fan that runs cooler lasts years longer in a hot roof space.

How Many Fans Does a Warehouse Need?
Start with the volume of the building and how many times you want to change the air each hour. Greenheck, a US fan maker, says summer ventilation in warehouses changes the air 1 to 3 times an hour. Hot or busy buildings in the Kingdom often need more. Use this formula: CFM = building volume in cubic feet x air changes per hour ÷ 60.
Take a warehouse in Riyadh's Second Industrial City that is 40 m long, 25 m wide and 8 m high. That is 8,000 m³, or about 282,500 cubic feet. At 6 air changes an hour, it needs about 28,250 CFM of exhaust. That could be six fans of about 4,700 CFM each along one long wall, with air intakes on the opposite wall.
Always check the airflow at real pressure, not free air. Many listings give only the free air figure, but louvers, guards and wind cut the real amount. Lab tests under AMCA 210 or ISO 5801 give airflow at set pressures, so ask for those curves when you compare models.

Get a Quote for Your Project
Send us the size of the building or the wall opening, your power supply, and what the air carries, such as heat, dust or fumes. For a replacement, a photo of the old nameplate is enough to start. Tell us if the area has fuel, paint or gas, so we can offer a model rated for hazardous areas. We deliver from Riyadh across the Kingdom, including Dammam, Jubail, Jeddah and Yanbu. What does your fan need to move?
See all prices in our exhaust fan price guide
Frequently Asked Questions
Should I choose an axial or a centrifugal fan?
Choose axial when the air moves through a wall, a short duct or an open space. Choose a centrifugal blower when the air must pass through long ducts, filters or a kitchen hood. If you are not sure, send us the duct layout and we will check the pressure.
What does 630 mean on a fan?
It is the blade diameter in millimetres, so a 630 mm fan has blades about 63 cm across. It is a common size for cooling and exhaust, and we have it in single phase for sites without three phase power.
Do I need an explosion proof fan?
You need one wherever flammable gas, vapour or dust can be in the air, such as fuel stations, paint booths and chemical stores. Your consultant or the site drawings will show the hazardous zone. Send us the zone, and we will match a certified model.
Can these fans work with a duct?
Yes, if the duct is short and has few bends. Tube axial and vane axial models are made to sit in a duct and hold more pressure than a plain wall fan. For long ducts with filters, a centrifugal blower is the better choice.
How many air changes does a warehouse need?
Summer ventilation in warehouses usually changes the air 1 to 3 times an hour, and hot or busy sites need more. Multiply the building volume by that number, then divide by 60 to get CFM. Send us the size of your building and we will do the sum for you.