Cloud Electricals Co
Ceiling Cassette Exhaust Fan

TAT QCA Ceiling Cassette Exhaust Fan

TAT QCA ceiling cassette exhaust fans are compact concealed centrifugal fans for bathroom exhaust, toilet ventilation, pantry exhaust, laundry ventilation, and false-ceiling ducted ventilation in Saudi Arabia projects.

Bathroom & toilet exhaust
False ceiling installation
Saudi project quotation support
TAT QCA ceiling ducted centrifugal exhaust fan with grille and duct spigot
TAT QCA Ceiling Cassette Exhaust Fan

Application

Ceiling ducted exhaust

Mounting

False ceiling / gypsum ceiling

Airflow

50-308 CFM model range

Fan Type

Ceiling Cassette Exhaust Fan

Fan Design

Concealed Centrifugal

Model Series

TAT QCA Series

Airflow Range

50-308 CFM

Duct Connection

4 in / 6 in Options

Usage

Bathroom, Toilet, Pantry & Commercial Exhaust

Model Range

TAT QCA Model Range

QCA models are selected by required airflow, ceiling opening, duct size, voltage, noise target, and room application. Final quotation should confirm voltage, quantity, project location, and ceiling/duct layout.

ModelVoltageFrequencyPowerCFM RangeNoiseWeightDuct Connection
TAT-50QCA127V / 240V60Hz / 60-50Hz19W / 17W50-53 CFM30-34 dB(A)Approx. 2.0 kg4 in / 100 mm
TAT-80QCA127V / 240V60Hz / 60-50Hz20W / 17W80-85 CFM33-34 dB(A)Approx. 2.0 kg4 in / 100 mm
TAT-120QCA127V / 240V60Hz / 60-50Hz39W / 42W121-124 CFM37 dB(A)Approx. 2.0 kg4 in / 100 mm
TAT-160QCA127V / 240V60Hz / 60-50Hz32W / 35W160-165 CFM30-31 dB(A)Approx. 4.0 kg6 in / 150 mm
TAT-240QCA127V / 240V60Hz / 60-50Hz40W / 47W241-244 CFM35-36 dB(A)Approx. 4.0 kg6 in / 150 mm
TAT-300QCA127V / 240V60Hz / 60-50Hz51W / 62W301-308 CFM39-40 dB(A)Approx. 4.0 kg6 in / 150 mm
Product Overview

Ceiling cassette exhaust fan for bathroom and commercial ventilation

The TAT QCA Series is a compact ceiling cassette centrifugal exhaust fan designed for hidden installation above false ceilings, gypsum ceilings, and ceiling tile layouts. It is used where a standard wall exhaust fan is not suitable and the air must be discharged through a duct route.

This type of fan is commonly selected for bathrooms, toilets, en-suites, laundry rooms, utility closets, commercial restrooms, pantry areas, and light commercial ventilation points. The centrifugal fan design helps overcome resistance from short duct runs and flexible duct connections.

For Saudi Arabia projects, QCA ceiling exhaust fans are useful when contractors and MEP teams need a neat ceiling grille, ducted discharge, compact installation depth, and a clear model range for procurement and submittal review.

Features

Key Features

Practical construction and installation features for ducted ceiling exhaust applications.

Low-profile concealed ceiling installation for gypsum and false-ceiling spaces

Centrifugal fan design for ducted exhaust and higher resistance than simple grille fans

Removable architectural white PVC louvre grille for room-side finish

Galvanized iron sheet chassis with anti-rust zinc treatment

Integrated butterfly backdraft shutter at the discharge spigot

Ball bearing motor designed for continuous-duty ventilation operation

Thermal overload protection for motor safety

4 inch and 6 inch duct connection options across the model range

Specifications

Technical specifications

Final fan selection should confirm airflow, pressure, voltage, installation, accessories, and project approval requirements.

SpecificationAvailable Options / Details
Product CategoryCeiling Fan
Product TypeCeiling cassette concealed centrifugal exhaust fan
Model SeriesTAT QCA Series
Model RangeTAT-50QCA, TAT-80QCA, TAT-120QCA, TAT-160QCA, TAT-240QCA, TAT-300QCA
InstallationFalse ceiling, gypsum ceiling, ceiling tile, or concealed ceiling void
Airflow Range50-308 CFM catalog reference
Voltage127V and 240V options shown in model data
Frequency60Hz and 60/50Hz options shown in model data
Power Range17W to 62W model-dependent
Noise Range30-40 dB(A) catalog reference
Face Panel Size170 x 170 mm, 240 x 240 mm, 300 x 300 mm, or 320 x 320 mm depending on model
Ceiling Cut-out145 x 145 mm, 210 x 210 mm, 260 x 260 mm, or 290 x 290 mm depending on model
Duct Connection4 inch / 100 mm and 6 inch / 150 mm options
ConstructionGalvanized iron chassis with UV-stabilized white PVC grille
Backdraft ProtectionIntegrated spring-assisted butterfly shutter
ApplicationsBathrooms, toilets, commercial restrooms, pantries, laundry rooms, utility closets, and light commercial ducted exhaust
DocumentationDatasheet, quotation, technical submittal, and procurement documents on request
Applications

Applications

Common buyer use cases for QCA ceiling ducted exhaust fans.

Bathroom exhaust

Removes humidity, odor, and stale air through a concealed duct route.

Toilet ventilation

Supports toilet exhaust where a ceiling grille and duct connection are required.

Commercial restrooms

Useful for offices, clinics, retail spaces, and public restroom ventilation.

Pantry exhaust

Removes light odor, warm air, and stale air from pantry and small service areas.

Laundry rooms

Helps remove humidity and stale air from light-duty laundry or utility areas.

Gypsum ceiling projects

Fits concealed installations where visible equipment should be minimal.

Hotel rooms and apartments

Suitable for en-suite bathrooms and compact ducted exhaust points.

MEP project supply

Selected by CFM, duct size, ceiling cut-out, voltage, and quantity.

Selection support

What to Send for Correct Selection

To select the correct QCA model, share the room type, required airflow, ceiling opening, duct size, voltage, quantity, and project city. Drawings or ceiling layouts help confirm the right fan size before quotation.

01

Application: bathroom, toilet, pantry, laundry, restroom, or utility room

02

Required airflow in CFM or room size

03

Ceiling cut-out size or available ceiling space

04

Duct connection size: 4 inch or 6 inch

05

Duct route length and number of bends if available

06

Voltage and frequency requirement

07

Noise requirement for occupied spaces

08

Quantity and Saudi project city/location

Accessories

Accessories & Installation Items

Accessory requirements depend on the ceiling detail, duct route, control method, and discharge point.

Flexible Duct

Duct Clamp

Backdraft Damper

Ceiling Grille

Speed Controller

Electrical Isolator

Downloads

Documents and procurement files

Product and company documents can be shared for contractor, consultant, and procurement review.

Product Datasheet

Request / Download

Technical Submittal

Request / Download

Company Profile

Request / Download

CR / VAT / ISO / COC

Request / Download

Quotation Sheet

Request / Download
Related Products

Related ventilation products

FAQ

QCA Ceiling Cassette Fan FAQ

Short answers for contractors, procurement teams, and MEP engineers selecting ceiling cassette exhaust fans.

Send the model if known, required CFM, room type, ceiling cut-out, duct size, voltage, frequency, quantity, and project city.

Quotation Request

Request QCA Ceiling Cassette Exhaust Fan Quotation

Send your room type, required airflow, ceiling opening, duct size, voltage, quantity, and Saudi project location. Our team can help select the suitable QCA model for quotation.

WhatsApp Instead